Description
A new addition to the SRT range of room thermostats, offering the latest in energy saving and wireless remote control technology.
SRT323 is a single-box solution that includes time-proportional integral (TPI) software and an interoperable radio.
It can be used as a direct replacement for existing thermostats without the need for wiring changes, while the TPI software optimises boiler firing to help maintain the set temperature without 'overshooting'. It has been shown that TPI controllers can provide considerable energy savings compared with traditional heating controllers. The interoperable radio enables you to remotely change the set point, read the temperature or receive alerts. SRT323 is an ideal partner for use with a home gateway for web-enabled apps, allowing you to remotely control your heating while on the move. You no longer have to worry about returning to a cold house, as long as you have a smartphone or tablet PC handy.
Features
- Battery operated, no mains wiring needed
- TPI temperature control software
- Clear back-lit digital display
- Temperature range 5 degrees C to 30 degrees C
- Standard wall plate
- Easy to install and use
- Local and remote set point control
- Measured temperature can be read remotely
- Operates as a standalone product if no network is available
Specifications
Electrical
Purpose of Control : Electronic Room Thermostat + RF (Independently Mounted)
Contact Rating : 3(1)A 230V AC
Contact Type : Micro-Interruption
Supply : 3V dc. (2 x AAA Alkaline Batteries)
Control Action : Type 1B
Operating Time Limitation : Intermittent
Software Class : Class A
Radio
Compliance : Z-Wave Compliant
RF Frequency : 868.42 MHz (EU)
Receiver Category : Category 3
Power Class : Class B
RF Range : >100m line of sight
Mechanical
Dimensions : 86mm x 86mm x 36.25mm
Weight (single unit packing) : 200 +- 30g
Case Material : Thermoplastic, flame retardant
Ball Pressure Test Temperature : 75 degrees C
Mounting : Wall Plate
Environmental
Impulse Voltage Rating : Cat II 2500V
Enclosure Protection : IP30
Pollution Degree : Degree 2
Operating Temperature Range : 0 degrees C to +40 degrees C
Compliance